To use a torque screwdriver, take the screw's torque from the equipment manual, fit the bit that fills the head, unlock the adjuster, set the value and lock it. Seat the bit square and turn clockwise, slowly, until the handle slips or clicks. Then stop. On a part held by several small screws, such as a robot end effector, run every screw down snug with a plain bit driver first, then torque them in a cross pattern, in two passes. The torque handle only tightens; it never loosens.
TL;DR
- Take the value from the equipment manual, then unlock, set and lock. 1 to 5 Nm is 8.9 to 44.3 in-lb.
- Fit the bit that fills the head: on standard cap screws, 3 mm hex for M4 and 4 mm for M5, or T20 and T25 on the hexalobular versions.
- Remove old screws and run new ones down snug with a plain bit driver. Then torque them in a cross pattern, in two passes.
- Keep the bit square in the head, turn slowly, and stop at the first slip or click. No extra nudge.
- Never loosen with it, never put an extension on the handle, and recalibrate at least every 12 months or about 5,000 cycles.
Table of Contents
- What a torque screwdriver does, and what it does not
- Match the bit to the screw
- Before you start
- How to use a torque screwdriver, step by step
- Worked example: an end effector and its sensor
- What it costs when this goes wrong
- Our perspective
- The tools for end effector torque work
- FAQ
- Sources
What a torque screwdriver does, and what it does not
An adjustable torque screwdriver is a handle with a spring and a clutch inside. When the screw resists with the set torque, the handle releases and resets itself. The hand torque tool standard, ISO 6789, files it as a Type II Class D tool (a screwdriver, adjustable and graduated) with a permitted deviation of plus or minus 6 percent.
The release comes in two forms, and it matters which one is in your hand:
- Click type. One maker's manual says to turn clockwise until a click or impulse is heard or felt. The handle still drives the screw if you keep pushing past it.
- Slipper or cam-over type. The clutch disengages at the set value, so the handle spins free. One maker's instructions say the screwdriver will slip when pre-set torque is reached and reset itself.
Either way, three limits apply:
- It measures in one direction. Another maker's leaflet says the tool can only be operated clockwise to check the torque and must not be used to loosen screw connections.
- It controls torque, not clamp. Dirty threads or old threadlocker use up torque before the head clamps the part.
- It is commonly not insulated. The same leaflet warns against using it on live electrical circuits.
Match the bit to the screw
Small machine parts are mostly held by metric socket head cap screws with a hex or hexalobular (Torx) socket. Two standards set the drive size: ISO 4762 for hex socket cap screws and ISO 14579 for the hexalobular versions.
| Screw | Hex socket (ISO 4762) | Hexalobular socket (ISO 14579) |
|---|---|---|
| M3 | 2.5 mm | T10 |
| M4 | 3 mm | T20 |
| M5 | 4 mm | T25 |
| M6 | 5 mm | T30 |
Two checks before you trust the table:
- Look at the screw, not the drawing. Low head, button head and countersunk screws often take a smaller drive than a standard cap screw on the same thread.
- Fill the head completely. A bit one size small rounds out the socket as the torque peaks.
A torque screwdriver is only as accurate as the bit in the screw. A loose bit cams out of the head before the clutch ever releases.
Before you start
- The value and the units. Nm, in-lb or kgf-cm: convert before you touch the scale.
- The range. A figure outside your scale needs a different tool, not a guess.
- Calibration date. ISO 6789 gives a default recalibration interval of 12 months, or approximately 5,000 cycles, when the user runs no control procedure of their own.
- Clean threads. One robot maker's service manual tells technicians to clear old threadlocker residue out of the screw holes to get the correct torque on new screws.
How to use a torque screwdriver, step by step
- Pick the bit. Match it to the screw head using the table. A 1/4 inch hex bit swaps between bit driver and torque handle.
- Unlock the adjuster. On many designs you hold the body and pull the adjusting knob back. Others use a ring or a push lock.
- Set the value. Turn the adjuster until the scale reads your value, never outside the marks.
- Lock it. Push the lock home, then read the scale again in case it moved.
- Exercise the tool. One robot maker's manual says to click the torque tools a minimum of three times before use to get the calibrated torque.
- Run the screws down snug. With the plain bit driver, bring every screw down until the head just touches the part.
- Seat the bit square. Move the bit to the torque handle, hold it at 90 degrees to the screw, as one maker's instructions describe, hand centered on the grip.
- Turn slowly, clockwise, until it releases. Steady twists, not a snap. A slipper handle spins free; a click handle clicks. Stop there.
- Work in a cross pattern, in two passes. Corner to opposite corner: a first pass at a lower setting, then full value in the same order.
- Mark it. Many sites paint mark each torqued screw so a missed one shows.
- Put it away. Some makers' leaflets say to store it at its lowest torque setting and never force it below; others say nothing. Follow the leaflet that came with your own tool.
Worked example: an end effector and its sensor
On a wafer transfer or EFEM robot, the end effector is the blade that carries the wafer. It is commonly held to the arm by a few small cap screws, sometimes with leveling screws, while a wafer presence sensor uses much smaller Torx screws. The torque values belong to the robot maker; take them from that manual only. A typical swap:
- Remove the old blade with the plain bit driver, never the torque handle.
- Place washers or spacers with a fine plier rather than fingers, so nothing drops into the arm.
- Snug all the mounting screws with the bit driver so the blade seats flat, then set leveling screws if the manual calls for it.
- Torque the mounting screws in a cross pattern: a low first pass, then the final value.
- Refit the sensor with a precision driver. If the manual gives a sensor value under 1 Nm, it is below a 1 to 5 Nm scale; use the method the manual names.
- Re-teach and test. Check leveling and the station positions before the first real wafer.
A blade that shifts by a fraction of a millimeter changes where the wafer lands. That is why the screws get a number, not a feel.
What it costs when this goes wrong
Small screws give little warning before a thread strips. The common failures:
- The second turn. Turning again after a click to be sure adds torque the tool never measured. Over tightening, as one maker's leaflet puts it, may result in breakage. A slipper handle protects you here; a click handle does not.
- One screw at a time to full value. Each screw relaxes the ones done before it. A study of tightening order on bolted rotors found a cross pattern with an additional tightening pass gave stiffer joints and less preload loss than a single pass.
- Using it as a breaker. Loosening a seized screw with the torque handle risks the mechanism. Makers say do not use a torque instrument to break fasteners loose, and not to put an extension on the handle.
- A tool out of date. An unchecked torque screwdriver still releases, just at the wrong number.
Our perspective
A torque screwdriver is a small tool doing a measuring job, so most of the skill sits around the release: the right bit, clean threads, a plain driver for the hard turning, a cross pattern and a light hand. We built the end effector kit around that sequence, with a slipper type handle that cannot be pushed past the set value.
One limit, stated plainly: the torque set's hex bits are 2, 3, 4, 5 and 6 mm, so it fits M4 and M5 hex cap screws but not M3 hex cap screws, which take 2.5 mm. Its TX10 bit does fit hexalobular M3.
Stop at the first release. The tool already did the measuring; a second turn only undoes it.
The tools for end effector torque work
The Teng Tools Robot End Effector Torque and Torx Kit, 46 pieces, carries what the steps above use:
- A 38 piece 1 to 5 Nm (8.9 to 44.3 in-lb) torque screwdriver set accurate to plus or minus 6 percent and conforming to ISO 6789, with a slipper handle, Nm scale and push lock. S2 bits: hex 2 to 6 mm, TX8 to TX40, TPX, PH, PZ, square and flat, plus a 1/4 inch square adaptor, in a FOAM1 tray.
- A 193 mm 1/4 inch hex magnetic bit driver that takes the set's bits to break screws loose and run them down, so the torque handle only sets the final figure.
- A 6 piece CrMo precision Torx screwdriver set, TX6, TX7, TX8, TX9, TX10 and TX15, for sensor and encoder screws in tight spots.
- A 140 mm mini long nose plier with long straight jaws to place and hold washers, spacers and small parts.
Check your robot maker's manual for drive sizes, torque values and any cleanroom tool rule before the first job. Browse the semiconductor field service tool kits for other fab equipment jobs, or the torque equipment range for other values.
FAQ
How do you set a torque screwdriver?
Unlock the adjuster, turn it until the scale reads the value from the equipment manual, then lock it again and read the scale a second time. Many designs use a knob or ring you pull back to unlock and push home to lock. Check the units first: 1 Nm is about 8.9 in-lb.
Can you use a torque screwdriver to loosen screws?
No. Torque screwdriver makers' instructions say the tool is a measuring instrument that works clockwise only and must not be used to break fasteners loose. Remove and run down screws with an ordinary bit driver, and keep the torque handle for the final tightening.
Does a torque screwdriver click or slip?
It depends on the design. Click types give a click or impulse at the set value and can still be turned further if you keep pushing. Slipper or cam-over types disengage the drive at the set value, so the handle spins free and cannot add more torque. Both reset themselves for the next screw.
How often does a torque screwdriver need calibrating?
ISO 6789 gives a default of 12 months or about 5,000 cycles when the user has no control procedure of their own. Recalibrate sooner if the tool is dropped, overloaded or used every day on critical work, and keep the certificate with the tool.
What hex and Torx bits do M3, M4 and M5 cap screws take?
Standard hex socket cap screws take a 2.5 mm hex for M3, 3 mm for M4 and 4 mm for M5. The hexalobular versions take T10 for M3, T20 for M4 and T25 for M5. Always confirm on the screw itself, because low head and button head screws often use a smaller drive.
Sources
- ISO 6789:2003 Assembly Tools for Screws and Nuts, Hand Torque Tools (sample), ISO
- 57032 Micrometer Adjustable Torque Screwdriver Owner's Manual, Klein Tools
- Ergo Micro Torque Screwdriver Operating Instructions, Mountz
- Torque Screwdriver Instruction Manual, GEARWRENCH
- e-Series Joint Replacement Manual, Universal Robots
- Socket Head Cap and Countersunk Screws, ISO 4762 Dimensions, RoyMech
- DIN EN ISO 14579 Hexalobular Socket Head Cap Screws, Fasten.it
- Numerical Analysis on Tightening Strategy of Long Bolts in a Multi-Stage Compressor, Chen and Chen, GPPS Shanghai 2025